Accident Report Detail
Accident Summary Nr: 200263358 - Employee Suffocates in Grain Bin Collapse
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 311363121 | 01/17/2008 | 5153 | 424510 | Mcalister Grain Company |
Abstract: On January 16, 2008, Employee #1 entered a soybean grain bin to clear a clog. A coworker was assisting him from the outside and maintained communication by radio. The coworker left to check the belt conveyor, which ran underneath the grain bin. While he was gone, Employee #1 was engulfed in soy beans. After trying unsuccessfully to contact him, the coworker called the office to get emergency help. Employee #1 remained in the bin for several hours while emergency personnel attempted to rescue him. An additional collapse of soy beans completely engulfed his body, asphyxiating and killing him. At approximately 9:00 p.m., the body was removed and taken to the Coroner's office in Little Rock for autopsy.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 311363121 | Fatality | Asphyxia | Occupation not reported |
Translate