Accident Summary Nr: 173114.015 - Employee is fatally injured by failed skid loader arm during
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1795886.015 | 01/06/2025 | 423830 | Tls Equipment |
Abstract: At 9:00 a.m. on January 3, 2025, Employee #1 was spray painting a GEHL skid loader while kneeling on the floor beneath the equipment. During the task, the skid loader arm catastrophically failed, resulting in a rapid loss of hydraulic fluid. The failure caused the loader's back plate to fall onto Employee #1, causing fatal injuries.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1795886.015 | 35 | M | Fatality | Painting and paint spraying machine operators |