Accident Report Detail
Accident Summary Nr: 172528.015 - Employee is fatally injured in pneumatic loader tire explosi
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1756159.015 | 06/14/2024 | 922160 | Los Angeles County Fire Department |
Abstract: At approximately 2:08 p.m. on June 14, 2024, LACFD was called out to assist with a front-end loader on fire. As the firefighters were combating the fire, the left rear tire of the loader exploded, fatally injuring Employee #1. Employee #1 was standing approximately 3 to 5 feet from the tire at the time of the explosion. The blast caused debris to be ejected over 300 feet, breaking the driver's side window of Fire Engine 93 (FE93). A coworker, also a firefighter, who was near Employee #1, was also injured by the explosion and was taken to a trauma center for evaluation but was released later. Employee #1, with 19 years of experience, was wearing full personal protective equipment, including a self-contained breathing apparatus. The explosion was caused by increased internal pressure in the tire from the fire and the ignition of flammable compounds. A citation was issued to the employer for failure to provide proper hazard identification, evaluation, and training on large equipment tire explosion risks.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1756159.015 | 52 | M | Fatality | Firefighting occupations |