Accident Report Detail
Accident Summary Nr: 172050.015 - Employee sustains burns while plasma cutting drum top, later
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1789436.015 | 11/21/2024 | 811198 | Mayer Repair Llc |
Abstract: At 11:00 a.m. on November 11, 2024, an employee working as a mechanic/welder for an automotive shop was using a a plasma cutter to cut the top off a 55-gallon metal drum. The employee was unaware the drum contained flammable liquids. The instant the plasma cutter touched the drum, the drum exploded upwards and came to rest in the adjacent stall. The explosion caused a localized fire due to the flammable liquid in the drum. The employee was sustained multiple contusions and burns to his abdomen, face, chest and arms in the explosion. The employee was flown to the emergency department of a medical center. At 6:52 p.m. on November 19, 2024, the employee died from his injuries.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1789436.015 | 47 | M | Fatality | Automobile mechanics |