Accident Report Detail
Accident Summary Nr: 170080865 - Three employees burned to death in hydrocarbon fire
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 107635211 | 08/02/1993 | 2911 | 0 | Exxon Company, Usa |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 107635203 | 08/03/1993 | 2911 | 0 | Hall-Buck Marine, Inc. |
Abstract: Employees #1 through #3 were working with drums A, B, C, D in a coker unit, which thermally cracks heavy residual feeds through a process called delayed coking. The employees were preparing to switch feed from the C drum to the D coke drum. This process involves opening and closing a number of valves. Employee #1 was on the 55 ft level where the switch valve was located. Employee #3 was also on the 55 ft level, approximately 50 ft away from Employee #1. Employee #2 was on the 40 ft level to prepare for the switch. Employee #1 told the controller over the radio to divert half of the feed flow to the D drum. At approximately the same time, they heard a noise and saw a vapor cloud rising from the vicinity of the feed pumps. The cloud ignited and fire went as high as the 141 ft level, fatally burning Employees #1, #2, and #3. Two other employees on the 40 ft level evacuated to safety. The leak was caused by a sudden failure of a 45 degree elbow in the 6 in. discharge line of the furnace feed pump(s).
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 107635211 | Fatality | Burn/Scald(Heat) | Occupation not reported | ||
| 2 | 107635211 | Fatality | Burn/Scald(Heat) | Occupation not reported | ||
| 3 | 107635203 | Fatality | Burn/Scald(Heat) | Occupation not reported |