Accident Report Detail
Accident Summary Nr: 170066831 - Mechanic's fingers amputated in trimmer
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 119538353 | 10/13/1994 | 3089 | 0 | Artform Industries, Incorporated |
Abstract: Thermoplastic material was being formed and die cut in a 1974 Koehring in-line thermoformer machine, model #2025, serial #6086. When the material jammed in the trimmer section of the machine the operator called Employee #1, the mechanic, to clear the machine jam. Employee #1 had cleared the jam and was pushing material down where it entered the trimmer when the trimmer activated. The die cut one of Employee #1's fingers and amputated part of two fingers and the thumb of the left hand. Employee #1 had neglected to turn off the trimmer section of the machine.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 119538353 | Hospitalized injury | Amputation | Helpers, mechanics and repairers |
Translate