Accident Report Detail
Accident Summary Nr: 170054183 - Employee killed when struck by headache ball
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 18470641 | 01/02/1992 | 1791 | 0 | Locklear Brothers Steel Erectors, Inc. |
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 18470682 | 01/02/1992 | 1622 | 0 | Blythe Industries, Inc. |
Abstract: Employee #1, an iron worker, was assisting in the landing of a load of rebar that was being lowered by a hydraulic crane, using the crane's #1 line. The #2 line, which was inactive, held a 200 lb headache ball above the employee. The crane operator inadvertently caused the #2 line to two-block, snapping the #2 cable and allowing the headache ball to fall, striking Employee #1 on the head. He died as a result of massive head trauma. The crane was equipped with an anti-two-block device on both the #1 and #2 lines, but parts had been removed for repair, making the safety device ineffective.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 18470641 | Fatality | Other | Structural metal workers | ||
| 2 | 18470682 | Occupation Not Listed |