Accident Report Detail
Accident Summary Nr: 169213.015 - Employee is killed when caught between stamp wheel and guard
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1767969.015 | 08/10/2024 | 331110 | Cf&I Steel, L.P. |
Abstract: At 10:15 a.m. on August 9, 2024, Employee #1 was servicing the North stamp wheel on the rail line with assistance from four other employees. While in the process of removing the faceplate to replace pin assemblies, Employee #1 failed to lock out the stamp wheel. As Employee #1 replaced the faceplate, the stamp wheel began to move back into the rail line. Employee #1 was caught between the stamp wheel and the rail line guardrail, sustaining multiple blunt force injuries. The employee was fatally injured and pronounced dead at the scene.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury |
|---|---|---|---|---|---|
| 1 | 1767969.015 | 26 | M | Fatality |
Translate