Accident Report Detail
Accident Summary Nr: 162141.015 - Employee is killed when head is crushed by stacker carriage
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1714263.015 | 12/05/2023 | 321920 | Konz Wood Products, Inc. |
Abstract: At 3:45 a.m. on December 5, 2023, three employees were operating a resaw stacker. Coworker #1 was operating the infeed side, while Coworker #2 trained Employee #1 on operating the stacker side. The resaw stacker takes pre-cut boards and rips them down to smaller sizes and then restacks them onto pallets. Coworker #1 stated that s/he was stopping the infeed and would just run through the remaining material on the resaw. Coworker #2 communicated with Employee #1 that s/he was going to go outside of the building to get a forklift, so that s/he could remove the palletized material from rollers that extended through an outside door on the backside of the stacker. When Coworker #2 pulled up to the door, s/he heard a crash. Coworker #2 exited the lift and looked through the doorway to see if Employee #1 was alright. Coworker #2 did not see Employee #1 and went back into the building, where s/he found Employee #1 unresponsive on the empty pallet side of the stacker. Employee #1 had attempted to free a jammed board that had been wedged between the stacker frame and the stacker carriage. When the board was freed, the stacker carriage fell and struck Employee #1 in the back of the head, resulting in crushing injuries to the skull and neck. Employee #1 was killed.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1714263.015 | 57 | M | Fatality | Machine operators, not specified |
Translate