Accident Report Detail
Accident Summary Nr: 157755.015 - Employee is killed after fall down manhole
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1681004.015 | 07/05/2023 | 237110 | Rock River Construction, Ltd. |
Abstract: At 12:45 p.m. on July 3, 2023, an employee climbed down a fixed ladder within a manhole structure to retrieve a stuck tool caught on a ladder rung. As the employee began to climb out of the manhole opening, the employee lost consciousness and fell approximately 30 feet to the bottom of the manhole. The employee died as a result of toxic, fatal levels of hydrogen sulfide gas exposure and blunt force injuries to the head, resulting from the fall.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Highway, road, street | Maintenance or repair | 30 | X | ||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 1681004.015 | 34 | M | Fatality | Construction Laborer | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Installing underground plumbing conduit Fatality Cause: |