Accident Report Detail
Accident Summary Nr: 148671.015 - Employee is killed when caught between drum and chassis
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1613605.015 | 08/07/2022 | 327320 | Con-Metal Concrete, Llc |
Abstract: At 2:15 p.m. on August 6, 2022, an employee was attempting to exit through the man-way of the drum vessel on a cement truck when the drum was activated. The vessel rotated while the employee's limbs were half-way out of the man-way. The employee suffered multiple body part amputations and a severed head, resulting in his death.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1613605.015 | 39 | M | Fatality | Carpenter |
Translate