Accident Report Detail
Accident Summary Nr: 146700.015 - Employee suffers head trauma when struck by cover
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1579779.015 | 02/23/2022 | 336411 | Space Exploration Technologies Corp. |
Abstract: At 12:44 p.m. on January 18, 2022, an employee, an integration technician, was performing pneumatic pressure checks on a Raptor V2 Engine while at the Integration Stand. The final step in the pressure check operation, venting, was done for the first time using an automated program as opposed to the normal manual method that had been used in previous operations. Immediately after initiating the automated venting, the employee was struck by the fuel controller cover which broke free from the controller module. The controller cover had sheared at the vertical to horizontal beveled seam, liberating the cover face from the assembly. The employee suffered a skull fracture and head trauma and was hospitalized in a coma for months.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1579779.015 | 39 | M | Hospitalized injury | Science technicians, n.e.c. |