Accident Report Detail
Accident Summary Nr: 14470140 - One killed, two injured in fall when work table collapses
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 897280 | 11/19/1986 | 3479 | 0 | Enamel Products & Plating Company |
Abstract: Employees #1 through #3 were standing on a table, changing the separator rolls on a 60 in. slitter. The table was supported in a horizontal position by a hydraulic cylinder and ram, which were located under the table and the forward section. The separator roll slipped from the slitter helper's hand and fell into the machine, breaking the hydraulic connection to the cylinder and ram that supported the table. This caused a loss of hydraulic pressure and the table dropped into the pit. Employee #1 fell 25 ft into the pit and was killed. Employee #2 also fell, but caught a handrail and climbed out of the pit. He injured his back, but was not hospitalized. Employee #3 was pinned by the hinged arm of the table under the equipment where the separator roll was located; he was hospitalized. The table had no safety stop, safety leg, or other safety devices in its hydraulic system.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 897280 | Fatality | Fracture | Occupation not reported | ||
| 2 | 897280 | Non Hospitalized injury | Strain/Sprain | Occupation not reported | ||
| 3 | 897280 | Hospitalized injury | Fracture | Occupation not reported |
Translate