Accident Report Detail
Accident Summary Nr: 144676.015 - Employee amputates index finger while removing hydraulic sh
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1578377.015 | 02/15/2022 | 236220 | Roval Group |
Abstract: At 10:40 a.m. on February 14, 2022, Employee #1 was attempting to remove hydraulic shoring that was stuck in the trench. Employee #1 was unable to dislodge the shoring with a removal tool, so he instructed a coworker to pull it with an excavator, as Employee #1 held the removal tool. As the coworker positioned the excavator and began lifting, Employee #1's finger was caught between the excavator and the removal tool, resulting in a finger amputation. The employee was hospitalized for treatment.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Multi-family dwelling | New project or new addition | 6 | |||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 1578377.015 | 49 | M | Hospitalized injury | Construction laborers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Excavation Fatality Cause: |