Accident Report Detail
Accident Summary Nr: 14454185 - Employee amputates index finger in hopper table
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 115041238 | 09/16/1991 | 2431 | 0 | Jeld-Wen Fiber Products Of Iowa |
Abstract: Employee #1 was replacing a pushing lug on the feed chain of a hopper table. He had shut off the feed chain, but did not shut down the power sander that was fed by the table. A door stile was pulled into the sander by the sanding drum, making the feed chain move. Employee #1's left index finger was pinched between the chain and the sprocket of the machine, and part of it was amputated. The hopper table had been shut off but not locked out, and it had not been interlocked with the sander.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 115041238 | Non Hospitalized injury | Amputation | Miscellaneous woodworking machine operators |
Translate