Accident Report Detail
Accident Summary Nr: 14412779 - Employee killed when struck by crane pendant
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 107612053 | 01/15/1991 | 3498 | 0 | Atlas Bradford |
Abstract: The employer had modified a bridge crane's pendant control nine years ago so that it was rigidly mounted and moved along a catwalk's guardrail (3 inches above). The crane operator held the travel button down and walked along the catwalk. There are three stairways leading to the catwalk with 2 in. tubular steel guards forming 90 degree angles with the catwalk's guardrail. Employee #1 was attempting to exit the catwalk onto the stairway. The crane operator thought that Employee #1 was going to step back and allow him to pass with the crane. When the employee stepped between the moving pendant and guardrail, the operator immediately released the travel button, but the crane coasted more than 6 ft before stopping. Employee #1 was "rolled" or pinned between the pendant and the top guardrail for several feet. He was killed.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 107612053 | Fatality | Other | Occupation not reported |