Accident Report Detail
Accident Summary Nr: 14400600 - AIR RECEIVER EXPLODED, KILLING EMPLOYEE
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 101803260 | 01/15/1986 | 7623 | 0 | Tidewater Compression Service |
Abstract: EMPLOYEE #1 WAS ASSIGNED THE TASK OF REPAIRING A 16 HORSEPOWER GASOLINE ENGINE, POWERING A WORTHINGTON AIR COMPRESSOR, AT A GAS WELL SITE. THE ENGINE WAS BACKFIRING EXCESSIVELY AND BLOWING APART AN INJECTOR GAS COUPLING. THE ENGINE AND COMPRESSOR WERE MOUNTED ON TOP OF A ROY E. HANSON JR. AIR RECEIVER, SER. #186730. ALTHOUGH THERE WERE NO WITNESSES TO THE ACCIDENT, IT APPEARS THAT THE ENDS (WELDS) OF THE RECEIVER BLEW OUT. THE FORCE OF THE EXPLOSION DROVE EMPLOYEE #1 INTO A GAS COMPRESSOR, THEN UP AND BEHIND THE COMPRESSOR. EMPLOYEE #1 WAS PROBABLY KILLED INSTANTLY.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 101803260 | Fatality | Concussion | Occupation not reported |
Translate