Accident Report Detail
Accident Summary Nr: 142708.015 - Two employees incur injuries, scissor lift is struck by cran
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1572347.015 | 01/12/2022 | 332312 | The George Evans Corporation |
Abstract: At 8:30 a.m. on January 11, 2022, Employee #1 was elevated inside a scissor lift resetting an underhung crane. Employee #2 was at ground level assisting Employee #1. Employee #1 reset the crane and the crane traveled towards Employee #1. The hook on the crane struck the guardrail on the scissor lift and displaced and tipped the scissor lift over along with Employee #1. Employee #2 was in the path of the scissor lift and was struck by the cage. Employee #1 was immediately knocked unconscious and was in a coma; Employee #2 had a broken pelvis, knee, foot and broken ribs. Both employees required hospitalization for their injuries.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1572347.015 | 64 | M | Hospitalized injury | Machinery maintenance occupations | |
| 2 | 1572347.015 | 56 | M | Hospitalized injury |