Accident Report Detail
Accident Summary Nr: 138275.015 - Employee suffers partial amputation of left arm while runnin
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1542780.015 | 07/20/2021 | 517919 | J&B Communications |
Abstract: At 3:30 p.m. on July 6, 2021, Employee #1 was running a 1/4 inch strand wire across a highway for utilities installation when a northbound vehicle ran over the strand. The vehicle pulled on the cable, causing a partial amputation of the employee's left arm about 5 inches below the elbow. A required Traffic Control Plan was neither obtained nor implemented, and guidance from Section VI of the Manual on Uniform Traffic Control Devices was not followed.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Other | |||||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1542780.015 | 27 | M | Hospitalized injury | Construction laborers |