Accident Report Detail
Accident Summary Nr: 131074.015 - Employee amputates finger when contacting unguarded cooling
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1490102.015 | 08/27/2020 | 312111 | Western Group Packaging, Llc |
Abstract: At 2:30 a.m. on August 22, 2020, an employee working as a production supervisor for a soft drink manufacturer was working with three coworkers troubleshooting a SMI SK800T Model ST5000 heat-shrink oven (serial number PC151191S2562). While troubleshooting the oven, the employee inadvertently contacted an unguarded cooling fan with his right hand. The employee amputated his index finger and was hospitalized.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1490102.015 | 35 | M | Hospitalized injury | Supervisors, production occupations |
Translate