Accident Report Detail
Accident Summary Nr: 127729.015 - Employee is struck, killed by truck's swinging boom leaf
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1483198.015 | 07/13/2020 | 238320 | Omega Coatings & Construction, Llc |
Abstract: At 8:30 a.m. on July 13, 2020, Employee #1 and a coworker, employed by a commercial surfacing company, were working in an enclosed area on the outside lane of a two-lane highway. They were abrasive blasting old paint beneath a bridge. Jersey-style concrete barriers 2.75 feet high were set up along the edge of the highway work zone. The highway's posted speed limit was 70 mph. After leaving the work zone to take a water break, the two employees began returning to their work area, walking inside and parallel to the concrete barriers. A boom truck drove by. The truck's boom leaf with clam shell bucket was swinging freely and crossed over the concrete barrier. The coworker was able to jump away from the swinging boom leaf. He yelled to warn Employee #1, but Employee #1 was unable to move out of the way. The boom leaf's bucket struck Employee #1 between his ribs and waist. Employee #1 sustained blunt force traumatic injuries and was killed.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Bridge | Alteration or rehabilitation | 0 | 0 | X | |||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 1483198.015 | 29 | M | Fatality | Construction laborers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Exterior painting Fatality Cause: |
Translate