Accident Report Detail
Accident Summary Nr: 124169.015 - Employee's finger is partially amputated in door
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1464309.015 | 02/20/2020 | 336390 | Aludyne Georgia Machining, Llc |
Abstract: At 2:45 a.m. on February 12, 2020, an employee, a maintenance worker, was repairing an OKK HM600 CNC machine. The ATC door next to the tool arm had become misaligned and the employee was in the process of removing it. The employee manually turned the tool arm, which caused the door to actuate and shut suddenly, pinching his left hand. The employee was hospitalized to treat a partial amputation of the distal phalange of his left middle finger.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1464309.015 | 41 | M | Hospitalized injury | Machinery maintenance occupations |
Translate