Accident Report Detail
Accident Summary Nr: 114075.015 - Employee is electrocuted while servicing escalator
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1381609.015 | 02/28/2019 | 811219 | Thyssenkrupp Elevator Corporation |
Abstract: On February 28, 2019, an employee was performing monthly preventative maintenance on two escalators. After opening the floor hatch to access components in the upper pit of the escalator, he used a hand pump sprayer to apply lubricant and fill oil reservoirs. The power supply of the escalator was not locked out. As the employee laid in a prone position with his feet oriented down the escalator steps and reached into the escalator pit, his left hand contacted with the interior of the open controller cabinet. As a result, the employee received electrical burns to his left hand and lower abdomen, as well as damage to his lungs. The employee was hospitalized, where he was in a coma, and died six days later.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1381609.015 | 38 | M | Hospitalized injury | Elevator operators |
Translate