Accident Summary Nr: 102156.015 - Employee dies from methane gas asphyxiation
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1287429.015 | 01/11/2018 | 212112 | Rockwell Mining Llc |
Abstract: At 2:00 p.m. on November 28, 2017, Employee #1 and a coworker were looking for drainage valves at a mine water treatment pond facility. Employee #1 went down a ladder into a manhole next to one of the ponds to look for the valve. Employee#1 fell off of the ladder as soon as his head got to ground level. He fell into the bottom of the twelve foot deep manhole and collapsed against a wall. Emergency services were contacted along with responders from MSHA. The MSHA personnel were the only people on site with gas detectors. The MSHA personnel found the oxygen level to be 5 percent and the methane level to be 15 percent in the manhole. A blower system was set up to clear the manhole of the methane gas before rescuers could retrieve Employee #1. Employee #1 died from asphyxiation before he could be rescued.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1287429.015 | 27 | M | Fatality | Laborers, except construction |