NAPHTHA (COAL TAR)†
| CAS # | 8030-30-6 |
|---|---|
| Formula |
Mixture |
| Synonyms |
crude solvent coal tar naphtha; solvent naphtha (coal) |
| Physical description | Colorless to dark reddish-brown colored liquid with an aromatic odor. | ||
|---|---|---|---|
| Boiling point | 200-500°F | Molecular weight | 110 (approx) |
| Freezing point/melting point | Vapor pressure | 6.72 mmHg | |
| Flash point | 100-109°F | Vapor density | |
| Specific gravity | 0.86-0.88 | Ionization potential | |
| Lower explosive limit (LEL) | Upper explosive limit (UEL) | ||
| NFPA health rating | NFPA fire rating | ||
| NFPA reactivity rating | NFPA special instruction | ||
| Vapor hazard ratio (VHR) | |||
| Historical exceedance percentage | |||
| Target organs | |||
| Analyte code (IMIS no.) | 0710 |
|---|---|
| Sampling group | |
| Sampler/Sampling media | CSC tube (100/50 mg) [SKC 226-01] |
| Sampling time* |
15 min |
| Sampling volume (TWA)* |
3 L |
| Sampling flow rate (TWA)* |
0.2 L/min |
| Sampling volume (STEL/Peak/C)* |
|
| Sampling flow rate (STEL/Peak/C)* |
|
| Analytical method instruments | GC-FID |
| Method reference | OSHA 48 (fully validated) |
| Notes |
|
| Special requirements |
|
* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.
| Wipe Sampler/Sampling media |
|
|---|---|
| Bulk Method |
|
| Device | Photoionization detector (PID) |
|---|---|
| Model/Type | |
|
Sampling information (see manufacturer instructions) |
|
OSHA PEL
8-hour TWA (ST) STEL (C) Ceiling Peak |
NIOSH REL
Up to 10-hour TWA (ST) STEL (C) Ceiling |
ACGIH TLV©
8-hour TWA (ST) STEL (C) Ceiling |
|||||
|---|---|---|---|---|---|---|---|
| PEL-TWA |
100 ppm (400 mg/m³) |
REL-TWA |
100 ppm (400 mg/m³) |
TLV-TWA |
|
PEL-TWA |
100 ppm (400 mg/m³) |
| PEL-STEL |
|
REL-STEL |
|
TLV-STEL |
|
PEL-STEL |
|
| PEL-C |
|
REL-C |
|
TLV-C |
|
PEL-C |
|
| Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
| Notes: |
Notes:
|
Notes:
TLV withdrawn in 2009. See Appendix H: Reciprocal Calculation Method for Certain Refined Hydrocarbon Solvent Vapor Mixtures |
Notes:
|
||||
| Health factors: See NIH-NLM PubChem. | IDLH |
1000 ppm |
|||||
| Carcinogenic classifications: Not listed |
Notes:
10% of LEL |
||||||
|
AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:
|
|||||||
Additional Resources and Literature References
|
NOAA: CAMEO Chemicals - Coal tar oil, [heavy distillate] NIOSH: Pocket Guide to Chemical Hazards - Naphtha (coal tar) Literature References
|
Last Updated Date : 01/05/2021